Sutures in dentistry
Siegfried Mixner is a Medical Advisor, not a dentist. The notes reflect experience from many training sessions in dental practices. The treatment decision always lies with the treating dentist.
Choosing needle, thread and size correctly. Hardly anyone in dental retail advises on this – here you will find the basics from the SMI catalogue and experience from dental practices.
- Monofilament has proven itself in periodontal and soft-tissue surgery – it keeps plaque accumulation on the thread under control.
- Fine sizes: 6/0 for recession coverage, 5/0 or 6/0 for flap surgery.
- Non-absorbable in periodontology, removal after 7 to 10 days.
- Not every situation needs a suture: membranes and implant exposures usually do not.
Which suture for what?
Experience from dental practices, collected by Siegfried Mixner
| Recession coverage / tunnel technique | Monofilament 6/0, needle DS16 – fine, but the needle is not too small and is still easy to grip. Alternatively DS19 or HRT19; the trend is towards the DS needle. |
|---|---|
| Flap surgery | 5/0 or 6/0. Practise the suturing technique thoroughly beforehand, using different techniques. |
| Socket preservation with collagen cone | A holding suture is possible but not strictly necessary. |
| Membranes (GBR/GTR) | In dental practice usually no suture needed – useful only in a few treatments. |
| Implant exposure | Usually no suture needed. |
| Suture removal | Non-absorbable sutures usually after 7 to 10 days. |
The needle: understanding the codes
At SMI the code stands for circle fraction and cross-section, the number after it for the needle length in millimetres. DS19 therefore means: 3/8 circle, cutting edge on the outside, 19 mm.
| DS / HS | 3/8 or 1/2 circle, triangular, cutting edge on the outside (reverse cutting) |
|---|---|
| DR / HR | 3/8 or 1/2 circle, round body, tapering to a point |
| DRT / HRT | 3/8 or 1/2 circle, round body with a triangular ground cutting tip |
| Easy Pass (P) | Precision tip with an additional grind – according to SMI 40–50 % better penetration than standard cutting needles |
A detailed needle guide by Siegfried Mixner will follow.
The thread: materials
Each material has its own properties. The data come from the SMI dental catalogue.
Non-absorbable
| Polypropylene | Monofilament, blue, non-absorbable, minimal tissue reaction. |
|---|---|
| PTFE | Monofilament, white. From practice: soft and not stiff, the thread lies nicely, the ends do not prick – patients hardly feel it. More expensive, though. |
| Supramid | Twisted, sheathed polyamide, black, becomes encapsulated by connective tissue. |
| Polyester | Braided, silicone-coated, green or white. |
| Silk | Braided, black; moderate tissue reaction. |
Absorbable
| Surgicryl Rapid | Braided (polyglycolic acid). Approx. 50 % tensile strength after approx. 7 days, fully absorbed after approx. 42 days. |
|---|---|
| Surgicryl 910 | Braided (polyglactin 910). 40–50 % tensile strength after approx. 21 days, absorbed after 56–70 days. |
| Surgicryl PGA | Braided (polyglycolic acid). Approx. 50 % tensile strength after approx. 21 days, absorbed after 60–90 days. |
| Surgicryl Monofast | Monofilament (polyglecaprone 25). Approx. 60 % tensile strength after approx. 7 days, absorbed after 90–120 days. |
| Surgicryl Monofilament | Monofilament (polydioxanone). Approx. 50 % tensile strength after 42 days, absorbed after 180–210 days. |
Do not use absorbable threads where the tissue needs long-term suture support (package insert). In periodontology they are generally not used.
Thread size: USP and EP
| USP | 7/0 · 6/0 · 5/0 · 4/0 · 3/0 |
|---|---|
| EP (1/10 mm) | 0,5 · 0,7 · 1 · 1,5 · 2 |
Frequently asked questions
Monofilament or braided – which is better in the mouth?
Monofilament threads have proven themselves in periodontal and soft-tissue surgery: the smooth surface keeps plaque accumulation along the thread under control. Braided threads are more supple and easier to knot, but take up more deposits.
Which suture for recession coverage?
Monofilament 6/0 with a DS16 needle has proven itself: the thread is fine, but the needle is not too small and is still easy to grip. Alternatively DS19 or HRT19 – the trend is towards the DS needle.
When are non-absorbable sutures removed?
Usually after 7 to 10 days.
Do I need absorbable sutures?
In periodontology generally not – non-absorbable threads are used there and removed after 7 to 10 days.
Does a membrane have to be sutured?
In dental practice usually not. A membrane suture makes sense only in a few treatments.
Why is PTFE more expensive – is it worth it?
PTFE is soft and not stiff. The thread lies nicely and the ends do not prick. Patients often feel stiff thread ends as pricking; they hardly feel PTFE.
What does 6/0 or 5/0 mean?
The USP size: the higher the number before “/0”, the finer the thread. 6/0 corresponds to EP 0.7 (0.07 mm), 5/0 corresponds to EP 1 (0.1 mm).
Order sutures
Sources: SMI dental catalogue, SMI package inserts; experience: Siegfried Mixner (Medical Advisor, not a dentist). For indications, contraindications and warnings, the manufacturer's package insert applies.
Coming soon: suturing techniques (which for what, how to practise at home), incision techniques and graft harvesting.