For dental professionals only. Orders exclusively from dental practices and specialist businesses. All prices net, plus 20 % VAT.
First Box Company logoProducts and services from Tyrol
EN
Cart 0
Home›Knowledge›Sutures
Guide · Surgery

Sutures in dentistry

By Siegfried Mixner, Medical Advisor · Updated: November 2026

Siegfried Mixner is a Medical Advisor, not a dentist. The notes reflect experience from many training sessions in dental practices. The treatment decision always lies with the treating dentist.

Choosing needle, thread and size correctly. Hardly anyone in dental retail advises on this – here you will find the basics from the SMI catalogue and experience from dental practices.

In short

Which suture for what?

Experience from dental practices, collected by Siegfried Mixner

Recession coverage / tunnel techniqueMonofilament 6/0, needle DS16 – fine, but the needle is not too small and is still easy to grip. Alternatively DS19 or HRT19; the trend is towards the DS needle.
Flap surgery5/0 or 6/0. Practise the suturing technique thoroughly beforehand, using different techniques.
Socket preservation with collagen coneA holding suture is possible but not strictly necessary.
Membranes (GBR/GTR)In dental practice usually no suture needed – useful only in a few treatments.
Implant exposureUsually no suture needed.
Suture removalNon-absorbable sutures usually after 7 to 10 days.

The needle: understanding the codes

At SMI the code stands for circle fraction and cross-section, the number after it for the needle length in millimetres. DS19 therefore means: 3/8 circle, cutting edge on the outside, 19 mm.

DS / HS3/8 or 1/2 circle, triangular, cutting edge on the outside (reverse cutting)
DR / HR3/8 or 1/2 circle, round body, tapering to a point
DRT / HRT3/8 or 1/2 circle, round body with a triangular ground cutting tip
Easy Pass (P)Precision tip with an additional grind – according to SMI 40–50 % better penetration than standard cutting needles

A detailed needle guide by Siegfried Mixner will follow.

The thread: materials

Each material has its own properties. The data come from the SMI dental catalogue.

Non-absorbable

PolypropyleneMonofilament, blue, non-absorbable, minimal tissue reaction.
PTFEMonofilament, white. From practice: soft and not stiff, the thread lies nicely, the ends do not prick – patients hardly feel it. More expensive, though.
SupramidTwisted, sheathed polyamide, black, becomes encapsulated by connective tissue.
PolyesterBraided, silicone-coated, green or white.
SilkBraided, black; moderate tissue reaction.

Absorbable

Surgicryl RapidBraided (polyglycolic acid). Approx. 50 % tensile strength after approx. 7 days, fully absorbed after approx. 42 days.
Surgicryl 910Braided (polyglactin 910). 40–50 % tensile strength after approx. 21 days, absorbed after 56–70 days.
Surgicryl PGABraided (polyglycolic acid). Approx. 50 % tensile strength after approx. 21 days, absorbed after 60–90 days.
Surgicryl MonofastMonofilament (polyglecaprone 25). Approx. 60 % tensile strength after approx. 7 days, absorbed after 90–120 days.
Surgicryl MonofilamentMonofilament (polydioxanone). Approx. 50 % tensile strength after 42 days, absorbed after 180–210 days.

Do not use absorbable threads where the tissue needs long-term suture support (package insert). In periodontology they are generally not used.

Thread size: USP and EP

USP7/0 · 6/0 · 5/0 · 4/0 · 3/0
EP (1/10 mm)0,5 · 0,7 · 1 · 1,5 · 2

Frequently asked questions

Monofilament or braided – which is better in the mouth?

Monofilament threads have proven themselves in periodontal and soft-tissue surgery: the smooth surface keeps plaque accumulation along the thread under control. Braided threads are more supple and easier to knot, but take up more deposits.

Which suture for recession coverage?

Monofilament 6/0 with a DS16 needle has proven itself: the thread is fine, but the needle is not too small and is still easy to grip. Alternatively DS19 or HRT19 – the trend is towards the DS needle.

When are non-absorbable sutures removed?

Usually after 7 to 10 days.

Do I need absorbable sutures?

In periodontology generally not – non-absorbable threads are used there and removed after 7 to 10 days.

Does a membrane have to be sutured?

In dental practice usually not. A membrane suture makes sense only in a few treatments.

Why is PTFE more expensive – is it worth it?

PTFE is soft and not stiff. The thread lies nicely and the ends do not prick. Patients often feel stiff thread ends as pricking; they hardly feel PTFE.

What does 6/0 or 5/0 mean?

The USP size: the higher the number before “/0”, the finer the thread. 6/0 corresponds to EP 0.7 (0.07 mm), 5/0 corresponds to EP 1 (0.1 mm).

Order sutures

Sources: SMI dental catalogue, SMI package inserts; experience: Siegfried Mixner (Medical Advisor, not a dentist). For indications, contraindications and warnings, the manufacturer's package insert applies.

Coming soon: suturing techniques (which for what, how to practise at home), incision techniques and graft harvesting.